Features
TIA/EIA-568B.2-1;ISO/IEO 11801;NEC/CEC Fire protection – IEC60332-1 (CM)
Application: Horizontal Communication Cable; for indoor installation
Wiring Scheme
ANSI/TIA/EIA-568-C.2: T568A & T568B
ISO/IEC 11801: 8-position conductor/pair assignment (1-2/3-6/4-5/7-8)
Cordage
Construction: 4 pairs, 7 strandsed oxyge-free copper,23 AWG, S/FTP CAT.8 Twin Bulk Cable
Pair Identification: Pair1= Blue/White Pair2= Orange/White Pair 3= Green/White Pair4= Brown/White
Outer Cable Diameter: 8.0mm ± 0.2 mm
Outer Jacket: PVC/LSZH Jacket
Plug
Type:Unshielded RJ45 8P8C CAT6A Modular Plug
Housing: UL listed 94V-0/1/2 flame retardant polycarbonate
IDC blades: phosphor bronze, gold plating over 100 μin of nickel in contact area
MECHANICAL
Retention: 50 N (11 lbf) for 60±5 s Installation Temperature: 0°C to +60°C
Mating cycle life: min 750 cycles Operating temperature: -20°C to +60°C
Tensile strength: ≥ 20 N per wire Minimum bend radius: 4 outer cable diameters